3. Producción
Browse
7 results
Search Results
- Some of the metrics are blocked by yourconsent settings
Item type:Publication, New Ultrasound Telediagnostic System for Low‐Resource Areas(Wiley, 2020-08-14)Billions of people around the world lack access to diagnostic imaging. To address this issue, we piloted a comprehensive ultrasound telediagnostic system, which uses ultrasound volume sweep imaging (VSI) acquisitions capable of being performed by operators without prior traditional ultrasound training and new telemedicine software capable of sending imaging acquisitions asynchronously over low Internet bandwidth for remote interpretation. The telediagnostic system was tested with obstetric, right upper quadrant abdominal, and thyroid volume sweep imaging protocols in Peru. Scans obtained by operators without prior ultrasound experience were sent for remote interpretation by specialists using the telemedicine platform. Scans obtained allowed visualization of the target region in 96% of cases with diagnostic imaging quality. This telediagnostic system shows promise in improving health care disparities in the developing world. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Testing telediagnostic obstetric ultrasound in Peru: a new horizon in expanding access to prenatal ultrasound(BioMed Central Ltd, 2021-12-01)Ninety-four percent of all maternal deaths occur in low- and middle-income countries, and the majority are preventable. Access to quality Obstetric ultrasound can identify some complications leading to maternal and neonatal/perinatal mortality or morbidity and may allow timely referral to higher-resource centers. However, there are significant global inequalities in access to imaging and many challenges to deploying ultrasound to rural areas. In this study, we tested a novel, innovative Obstetric telediagnostic ultrasound system in which the imaging acquisitions are obtained by an operator without prior ultrasound experience using simple scan protocols based only on external body landmarks and uploaded using low-bandwidth internet for asynchronous remote interpretation by an off-site specialist. Methods: This is a single-center pilot study. A nurse and care technician underwent 8 h of training on the telediagnostic system. Subsequently, 126 patients (68 second trimester and 58 third trimester) were recruited at a health center in Lima, Peru and scanned by these ultrasound-naïve operators. The imaging acquisitions were uploaded by the telemedicine platform and interpreted remotely in the United States. Comparison of telediagnostic imaging was made to a concurrently performed standard of care ultrasound obtained and interpreted by an experienced attending radiologist. Cohen’s Kappa was used to test agreement between categorical variables. Intraclass correlation and Bland-Altman plots were used to test agreement between continuous variables. Results: Obstetric ultrasound telediagnosis showed excellent agreement with standard of care ultrasound allowing the identification of number of fetuses (100% agreement), fetal presentation (95.8% agreement, κ =0.78 (p < 0.0001)), placental location (85.6% agreement, κ =0.74 (p < 0.0001)), and assessment of normal/abnormal amniotic fluid volume (99.2% agreement) with sensitivity and specificity > 95% for all variables. Intraclass correlation was good or excellent for all fetal biometric measurements (0.81–0.95). The majority (88.5%) of second trimester ultrasound exam biometry measurements produced dating within 14 days of standard of care ultrasound. Conclusion: This Obstetric ultrasound telediagnostic system is a promising means to increase access to diagnostic Obstetric ultrasound in low-resource settings. The telediagnostic system demonstrated excellent agreement with standard of care ultrasound. Fetal biometric measurements were acceptable for use in the detection of gross discrepancies in fetal size requiring further follow up. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Testing telediagnostic thyroid ultrasound in Peru: a new horizon in expanding access to imaging in rural and underserved areas(Springer Science and Business Media Deutschland GmbH, 2021-12-01)Thyroid ultrasound is a key tool in the evaluation of the thyroid, but billions of people around the world lack access to ultrasound imaging. In this study, we tested an asynchronous telediagnostic ultrasound system operated by individuals without prior ultrasound training which may be used to effectively evaluate the thyroid and improve access to imaging worldwide. Methods: The telediagnostic system in this study utilizes volume sweep imaging (VSI), an imaging technique in which the operator scans the target region with simple sweeps of the ultrasound probe based on external body landmarks. Sweeps are recorded and saved as video clips for later interpretation by an expert. Two operators without prior ultrasound experience underwent 8 h of training on the thyroid VSI protocol and the operation of the telemedicine platform. After training, the operators scanned patients at a health center in Lima. Telediagnostic examinations were sent to the United States for remote interpretation. Standard of care thyroid ultrasound was performed by an experienced radiologist at the time of VSI examination to serve as a reference standard. Results: Novice operators scanned 121 subjects with the thyroid VSI protocol. Of these exams, 88% were rated of excellent image quality showing complete or near complete thyroid visualization. There was 98.3% agreement on thyroid nodule presence between VSI teleultrasound and standard of care ultrasound (Cohen’s kappa 0.91, P < 0.0001). VSI measured the thyroid size, on average, within 5 mm compared to standard of care. Readers of VSI were also able to effectively characterize thyroid nodules, and there was no significant difference in measurement of thyroid nodule size (P = 0.74) between VSI and standard of care. Conclusion: Thyroid VSI telediagnostic ultrasound demonstrated both excellent visualization of the thyroid gland and agreement with standard of care thyroid ultrasound for nodules and thyroid size evaluation. This system could be deployed for evaluation of palpable thyroid abnormalities, nodule follow-up, and epidemiological studies to promote global health and improve the availability of diagnostic imaging in underserved communities. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Testing telediagnostic right upper quadrant abdominal ultrasound in Peru: a new horizon in expanding access to imaging in rural and underserved areas(Public Library of Science, 2021-08-01)Hepatic and biliary diseases are prevalent worldwide, but the majority of people lack access to diagnostic medical imaging for their assessment. The liver and gallbladder are readily amenable to sonographic examination, and ultrasound is a portable, cost-effective imaging modality suitable for use in rural and underserved areas. However, the deployment of ultrasound in these settings is limited by the lack of experienced sonographers to perform the exam. In this study, we tested an asynchronous telediagnostic system for right upper quadrant abdominal ultrasound examination operated by individuals without prior ultrasound experience to facilitate deployment of ultrasound to rural and underserved areas. METHODS: The teleultrasound system utilized in this study employs volume sweep imaging and a telemedicine app installed on a tablet which connects to an ultrasound machine. Volume sweep imaging is an ultrasound technique in which an individual scans the target region utilizing preset ultrasound sweeps demarcated by easily recognized external body landmarks. The sweeps are saved as video clips for later interpretation by an experienced radiologist. Teleultrasound scans from a Peruvian clinic obtained by individuals without prior ultrasound experience were sent to the United States for remote interpretation and quality assessment. Standard of care comparison was made to a same-day ultrasound examination performed by a radiologist. RESULTS: Individuals without prior ultrasound experience scanned 144 subjects. Image quality was rated "poor" on 36.8% of exams, "acceptable" on 38.9% of exams, and "excellent" on 24.3% of exams. Among telemedicine exams of "acceptable" or "excellent" image quality (n = 91), greater than 80% of the liver and gallbladder were visualized in the majority of cases. In this group, there was 95% agreement between standard of care and teleultrasound on whether an exam was normal or abnormal, with a Cohen's kappa of 0.84 (95% CI 0.7-0.98, p <0.0001). Finally, among these teleultrasound exams of "acceptable" or "excellent" image quality, the sensitivity for cholelithiasis was 93% (95% CI 68.1%-99.8%), and the specificity was 97% (95% CI 89.5%-99.6%). CONCLUSION: This asynchronous telediagnostic system allows individuals without prior ultrasound experience to effectively scan the liver, gallbladder, and right kidney with a high degree of agreement with standard of care ultrasound. This system can be deployed to improve access to diagnostic imaging in low-resource areas. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, 69 testing a telediagnostic obstetric ultrasound system without a trained sonographer in a low-resource Peruvian clinic(Elsevier, 2021-02-01)94% of all maternal deaths occur in low and lower middle-income countries. Lack of access to Obstetric (OB) ultrasound (US) may be one modifiable contributing factor. We studied the efficacy of an OB US protocol with telediagnostic US system (OB US system) implemented by health workers without prior US experience to increase access to imaging in low-resource settings.1 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, No sonographer, no radiologist: new system for automatic prenatal detection of fetal biometry, fetal presentation, and placental location(Public Library of Science, 2022-02-01)Ultrasound imaging is a vital component of high-quality Obstetric care. In rural and under-resourced communities, the scarcity of ultrasound imaging results in a considerable gap in the healthcare of pregnant mothers. To increase access to ultrasound in these communities, we developed a new automated diagnostic framework operated without an experienced sonographer or interpreting provider for assessment of fetal biometric measurements, fetal presentation, and placental position. This approach involves the use of a standardized volume sweep imaging (VSI) protocol based solely on external body landmarks to obtain imaging without an experienced sonographer and application of a deep learning algorithm (U-Net) for diagnostic assessment without a radiologist. Obstetric VSI ultrasound examinations were performed in Peru by an ultrasound operator with no previous ultrasound experience who underwent 8 hours of training on a standard protocol. The U-Net was trained to automatically segment the fetal head and placental location from the VSI ultrasound acquisitions to subsequently evaluate fetal biometry, fetal presentation, and placental position. In comparison to diagnostic interpretation of VSI acquisitions by a specialist, the U-Net model showed 100% agreement for fetal presentation (Cohen's κ 1 (p<0.0001)) and 76.7% agreement for placental location (Cohen's κ 0.59 (p<0.0001)). This corresponded to 100% sensitivity and specificity for fetal presentation and 87.5% sensitivity and 85.7% specificity for anterior placental location. The method also achieved a low relative error of 5.6% for biparietal diameter and 7.9% for head circumference. Biometry measurements corresponded to estimated gestational age within 2 weeks of those assigned by standard of care examination with up to 89% accuracy. This system could be deployed in rural and underserved areas to provide vital information about a pregnancy without a trained sonographer or interpreting provider. The resulting increased access to ultrasound imaging and diagnosis could improve disparities in healthcare delivery in under-resourced areas.
