3. Producción
Browse
2 results
Search Results
- Some of the metrics are blocked by yourconsent settings
Item type:Publication, Experimental determination of the gas flame velocity of Camisea-Peru(Centro de Información Tecnológica, 2020-01-01)El objetivo del presente trabajo de investigacin ha sido determinar la velocidad de llama del gas natural de Camisea-Per en un rango amplio de razn de equivalencia mediante un estudio experimental. Se ha implementado los clculos matemticos utilizando el mtodo de la teora trmica mediante MathCad y simulando en un mecanismo cintico actual utilizando el programa CHEMKIN. Se ha conseguido experimentalmente valores de velocidad de llama entre 5% al 10% mayor al metano 100% puro comparado con otros autores en un amplio rango de razn de equivalencia. Esto valida los resultados debido a que el gas ensayado es gas natural con 88.54% de metano y 10.32% de etano, mejorando de esta manera el banco de ensayo experimental del laboratorio de combustin y control de emisiones gaseosas. En conclusin, la metodologa empleada proporciona una adecuada base de datos de velocidad de llama para el gas natural de Camisea-Per. - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Design and experimental analysis of an improved burner with natural gas(Springer Science and Business Media B.V., 2021-06-01)This research aimed to improve the thermal performance of industrial cookstoves using natural gas in Metropolitan Lima to promote good use of energy and reduce the impacts of climate change. The methodology was to use an appropriate test bench under the international standards of fuel gases; the appropriate instrumentation was used to record the variables such as temperature, pressure, mass flow, and relative air humidity. The burner was installed in the prototype cookstove and test bench to perform the experimental part. After that, the powers and performances of several industrial cookstoves in the Peruvian market were determined for comparison with the design of the prototype cookstove following the experimental methodology of 02 international standards, one Latin American and one Asian. The burner designed and manufactured in previous research gave a wide range of natural gas power according to the working pressure used and high efficiency of approximately 57% compared to the cookstoves that are sold nationwide, which on average is 53%. The advantage of this prototype cookstove is that it uses operating pressures between 23 and 34 mbar compared to stoves in the Peruvian market that do not have a standard of the maximum gas pressure.