    Testing telediagnostic obstetric ultrasound in Peru: a new horizon in expanding access to prenatal ultrasound
    (BioMed Central Ltd, 2021-12-01)
    Ninety-four percent of all maternal deaths occur in low- and middle-income countries, and the majority are preventable. Access to quality Obstetric ultrasound can identify some complications leading to maternal and neonatal/perinatal mortality or morbidity and may allow timely referral to higher-resource centers. However, there are significant global inequalities in access to imaging and many challenges to deploying ultrasound to rural areas. In this study, we tested a novel, innovative Obstetric telediagnostic ultrasound system in which the imaging acquisitions are obtained by an operator without prior ultrasound experience using simple scan protocols based only on external body landmarks and uploaded using low-bandwidth internet for asynchronous remote interpretation by an off-site specialist. Methods: This is a single-center pilot study. A nurse and care technician underwent 8 h of training on the telediagnostic system. Subsequently, 126 patients (68 second trimester and 58 third trimester) were recruited at a health center in Lima, Peru and scanned by these ultrasound-naïve operators. The imaging acquisitions were uploaded by the telemedicine platform and interpreted remotely in the United States. Comparison of telediagnostic imaging was made to a concurrently performed standard of care ultrasound obtained and interpreted by an experienced attending radiologist. Cohen’s Kappa was used to test agreement between categorical variables. Intraclass correlation and Bland-Altman plots were used to test agreement between continuous variables. Results: Obstetric ultrasound telediagnosis showed excellent agreement with standard of care ultrasound allowing the identification of number of fetuses (100% agreement), fetal presentation (95.8% agreement, κ =0.78 (p < 0.0001)), placental location (85.6% agreement, κ =0.74 (p < 0.0001)), and assessment of normal/abnormal amniotic fluid volume (99.2% agreement) with sensitivity and specificity > 95% for all variables. Intraclass correlation was good or excellent for all fetal biometric measurements (0.81–0.95). The majority (88.5%) of second trimester ultrasound exam biometry measurements produced dating within 14 days of standard of care ultrasound. Conclusion: This Obstetric ultrasound telediagnostic system is a promising means to increase access to diagnostic Obstetric ultrasound in low-resource settings. The telediagnostic system demonstrated excellent agreement with standard of care ultrasound. Fetal biometric measurements were acceptable for use in the detection of gross discrepancies in fetal size requiring further follow up.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Assessment of a brief standardized obstetric ultrasound training program for individuals without prior ultrasound experience
    (Lippincott Williams & Wilkins, 2022-10-08)
    ABSTRACT: Obstetric volume sweep imaging (OB VSI) is a simple set of transducer movements guided by external body landmarks that can be taught to ultrasound-naive non-experts. This approach can increase access to ultrasound in rural/low-resources settings lacking trained sonographers. This study presents and evaluates a training program for OB VSI. Six trainees without previous formal ultrasound experience received a training program on the OB VSI protocol containing focused didactics and supervised live hands-on ultrasound scanning practice. Trainees then independently performed 194 OB VSI examinations on pregnancies >14 weeks with known prenatal ultrasound abnormalities. Images were reviewed by maternal-fetal medicine specialists for the primary outcome (protocol deviation rates) and secondary outcomes (examination quality and image quality). Protocol deviation was present in 25.8% of cases, but only 7.7% of these errors affected the diagnostic potential of the ultrasound. Error rate differences between trainees ranged from 8.6% to 53.8% ( P < 0.0001). Image quality was excellent or acceptable in 88.2%, and 96.4% had image quality capable of yielding a diagnostic interpretation. The frequency of protocol deviations decreased over time in the majority of trainees, demonstrating retention of training program over time. This brief OB VSI training program for ultrasound-naive non-experts yielded operators capable of producing high-quality images capable of diagnostic interpretation after 3 hours of training. This training program could be adapted for use by local community members in low-resource/rural settings to increase access to obstetric ultrasound.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Breast ultrasound volume sweep imaging: A new horizon in expanding imaging access for breast cancer detection
    (Wiley, 2022-07-08)
    The majority of people in the world lack basic access to breast diagnostic imaging resulting in delay to diagnosis of breast cancer. In this study, we tested a volume sweep imaging (VSI) ultrasound protocol for evaluation of palpable breast lumps that can be performed by operators after minimal training without prior ultrasound experience as a means to increase accessibility to breast ultrasound. METHODS: Medical students without prior ultrasound experience were trained for less than 2 hours on the VSI breast ultrasound protocol. Patients presenting with palpable breast lumps for standard of care ultrasound examination were scanned by a trained medical student with the VSI protocol using a Butterfly iQ handheld ultrasound probe. Video clips of the VSI scan imaging were later interpreted by an attending breast imager. Results of VSI scan interpretation were compared to the same-day standard of care ultrasound examination. RESULTS: Medical students scanned 170 palpable lumps with the VSI protocol. There was 97% sensitivity and 100% specificity for a breast mass on VSI corresponding to 97.6% agreement with standard of care (Cohen's κ = 0.95, P < .0001). There was a detection rate of 100% for all cancer presenting as a sonographic mass. High agreement for mass characteristics between VSI and standard of care was observed, including 87% agreement on Breast Imaging-Reporting and Data System assessments (Cohen's κ = 0.82, P < .0001). CONCLUSIONS: Breast ultrasound VSI for palpable lumps offers a promising means to increase access to diagnostic imaging in underserved areas. This approach could decrease delay to diagnosis for breast cancer, potentially improving morbidity and mortality.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Sustainable Volume Sweep Imaging Lung Teleultrasound in Peru: Public Health Perspectives from a New Frontier in Expanding Access to Imaging
    (Frontiers Media SA, 2023-01-01)
    Background: Pulmonary disease is a common cause of morbidity and mortality, but the majority of the people in the world lack access to diagnostic imaging for its assessment. We conducted an implementation assessment of a potentially sustainable and cost-effective model for delivery of volume sweep imaging (VSI) lung teleultrasound in Peru. This model allows image acquisition by individuals without prior ultrasound experience after only a few hours of training. Methods: Lung teleultrasound was implemented at 5 sites in rural Peru after a few hours of installation and staff training. Patients were offered free lung VSI teleultrasound examination for concerns of respiratory illness or research purposes. After ultrasound examination, patients were surveyed regarding their experience. Health staff and members of the implementation team also participated in separate interviews detailing their views of the teleultrasound system which were systematically analyzed for key themes. Results: Patients and staff rated their experience with lung teleultrasound as overwhelmingly positive. The lung teleultrasound system was viewed as a potential way to improve access to imaging and the health of rural communities. Detailed interviews with the implementation team revealed obstacles to implementation important for consideration such as gaps in lung ultrasound understanding. Conclusions: Lung VSI teleultrasound was successfully deployed to 5 health centers in rural Peru. Implementation assessment revealed enthusiasm for the system among members of the community along with important areas of consideration for future teleultrasound deployment. This system offers a potential means to increase access to imaging for pulmonary illness and improve the health of the global community.