3. Producción

Browse

Search Results

Now showing 1 - 7 of 7
  • Some of the metrics are blocked by your 
    Item type:Publication,
    New Ultrasound Telediagnostic System for Low‐Resource Areas
    (Wiley, 2020-08-14)
    Billions of people around the world lack access to diagnostic imaging. To address this issue, we piloted a comprehensive ultrasound telediagnostic system, which uses ultrasound volume sweep imaging (VSI) acquisitions capable of being performed by operators without prior traditional ultrasound training and new telemedicine software capable of sending imaging acquisitions asynchronously over low Internet bandwidth for remote interpretation. The telediagnostic system was tested with obstetric, right upper quadrant abdominal, and thyroid volume sweep imaging protocols in Peru. Scans obtained by operators without prior ultrasound experience were sent for remote interpretation by specialists using the telemedicine platform. Scans obtained allowed visualization of the target region in 96% of cases with diagnostic imaging quality. This telediagnostic system shows promise in improving health care disparities in the developing world.
  • Some of the metrics are blocked by your 
    Item type:Publication,
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Testing telediagnostic obstetric ultrasound in Peru: a new horizon in expanding access to prenatal ultrasound
    (BioMed Central Ltd, 2021-12-01)
    Ninety-four percent of all maternal deaths occur in low- and middle-income countries, and the majority are preventable. Access to quality Obstetric ultrasound can identify some complications leading to maternal and neonatal/perinatal mortality or morbidity and may allow timely referral to higher-resource centers. However, there are significant global inequalities in access to imaging and many challenges to deploying ultrasound to rural areas. In this study, we tested a novel, innovative Obstetric telediagnostic ultrasound system in which the imaging acquisitions are obtained by an operator without prior ultrasound experience using simple scan protocols based only on external body landmarks and uploaded using low-bandwidth internet for asynchronous remote interpretation by an off-site specialist. Methods: This is a single-center pilot study. A nurse and care technician underwent 8 h of training on the telediagnostic system. Subsequently, 126 patients (68 second trimester and 58 third trimester) were recruited at a health center in Lima, Peru and scanned by these ultrasound-naïve operators. The imaging acquisitions were uploaded by the telemedicine platform and interpreted remotely in the United States. Comparison of telediagnostic imaging was made to a concurrently performed standard of care ultrasound obtained and interpreted by an experienced attending radiologist. Cohen’s Kappa was used to test agreement between categorical variables. Intraclass correlation and Bland-Altman plots were used to test agreement between continuous variables. Results: Obstetric ultrasound telediagnosis showed excellent agreement with standard of care ultrasound allowing the identification of number of fetuses (100% agreement), fetal presentation (95.8% agreement, κ =0.78 (p < 0.0001)), placental location (85.6% agreement, κ =0.74 (p < 0.0001)), and assessment of normal/abnormal amniotic fluid volume (99.2% agreement) with sensitivity and specificity > 95% for all variables. Intraclass correlation was good or excellent for all fetal biometric measurements (0.81–0.95). The majority (88.5%) of second trimester ultrasound exam biometry measurements produced dating within 14 days of standard of care ultrasound. Conclusion: This Obstetric ultrasound telediagnostic system is a promising means to increase access to diagnostic Obstetric ultrasound in low-resource settings. The telediagnostic system demonstrated excellent agreement with standard of care ultrasound. Fetal biometric measurements were acceptable for use in the detection of gross discrepancies in fetal size requiring further follow up.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    69 testing a telediagnostic obstetric ultrasound system without a trained sonographer in a low-resource Peruvian clinic
    (Elsevier, 2021-02-01)
    94% of all maternal deaths occur in low and lower middle-income countries. Lack of access to Obstetric (OB) ultrasound (US) may be one modifiable contributing factor. We studied the efficacy of an OB US protocol with telediagnostic US system (OB US system) implemented by health workers without prior US experience to increase access to imaging in low-resource settings.
      1
  • Some of the metrics are blocked by your 
    Item type:Publication,
    No sonographer, no radiologist: new system for automatic prenatal detection of fetal biometry, fetal presentation, and placental location
    (Public Library of Science, 2022-02-01)
    Ultrasound imaging is a vital component of high-quality Obstetric care. In rural and under-resourced communities, the scarcity of ultrasound imaging results in a considerable gap in the healthcare of pregnant mothers. To increase access to ultrasound in these communities, we developed a new automated diagnostic framework operated without an experienced sonographer or interpreting provider for assessment of fetal biometric measurements, fetal presentation, and placental position. This approach involves the use of a standardized volume sweep imaging (VSI) protocol based solely on external body landmarks to obtain imaging without an experienced sonographer and application of a deep learning algorithm (U-Net) for diagnostic assessment without a radiologist. Obstetric VSI ultrasound examinations were performed in Peru by an ultrasound operator with no previous ultrasound experience who underwent 8 hours of training on a standard protocol. The U-Net was trained to automatically segment the fetal head and placental location from the VSI ultrasound acquisitions to subsequently evaluate fetal biometry, fetal presentation, and placental position. In comparison to diagnostic interpretation of VSI acquisitions by a specialist, the U-Net model showed 100% agreement for fetal presentation (Cohen's κ 1 (p<0.0001)) and 76.7% agreement for placental location (Cohen's κ 0.59 (p<0.0001)). This corresponded to 100% sensitivity and specificity for fetal presentation and 87.5% sensitivity and 85.7% specificity for anterior placental location. The method also achieved a low relative error of 5.6% for biparietal diameter and 7.9% for head circumference. Biometry measurements corresponded to estimated gestational age within 2 weeks of those assigned by standard of care examination with up to 89% accuracy. This system could be deployed in rural and underserved areas to provide vital information about a pregnancy without a trained sonographer or interpreting provider. The resulting increased access to ultrasound imaging and diagnosis could improve disparities in healthcare delivery in under-resourced areas.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Assessment of a brief standardized obstetric ultrasound training program for individuals without prior ultrasound experience
    (Lippincott Williams & Wilkins, 2022-10-08)
    ABSTRACT: Obstetric volume sweep imaging (OB VSI) is a simple set of transducer movements guided by external body landmarks that can be taught to ultrasound-naive non-experts. This approach can increase access to ultrasound in rural/low-resources settings lacking trained sonographers. This study presents and evaluates a training program for OB VSI. Six trainees without previous formal ultrasound experience received a training program on the OB VSI protocol containing focused didactics and supervised live hands-on ultrasound scanning practice. Trainees then independently performed 194 OB VSI examinations on pregnancies >14 weeks with known prenatal ultrasound abnormalities. Images were reviewed by maternal-fetal medicine specialists for the primary outcome (protocol deviation rates) and secondary outcomes (examination quality and image quality). Protocol deviation was present in 25.8% of cases, but only 7.7% of these errors affected the diagnostic potential of the ultrasound. Error rate differences between trainees ranged from 8.6% to 53.8% ( P < 0.0001). Image quality was excellent or acceptable in 88.2%, and 96.4% had image quality capable of yielding a diagnostic interpretation. The frequency of protocol deviations decreased over time in the majority of trainees, demonstrating retention of training program over time. This brief OB VSI training program for ultrasound-naive non-experts yielded operators capable of producing high-quality images capable of diagnostic interpretation after 3 hours of training. This training program could be adapted for use by local community members in low-resource/rural settings to increase access to obstetric ultrasound.
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Diagnosis of Pregnancy Complications Using Blind Ultrasound Sweeps Performed by Individuals Without Prior Formal Ultrasound Training
    (Lippincott Williams and Wilkins, 2023-05-01)
    To estimate the diagnostic accuracy of blind ultrasound sweeps performed with a low-cost, portable ultrasound system by individuals with no prior formal ultrasound training to diagnose common pregnancy complications. Methods: This is a single-center, prospective cohort study conducted from October 2020 to January 2022 among people with second- and third-trimester pregnancies. Nonspecialists with no prior formal ultrasound training underwent a brief training on a simple eight-step approach to performing a limited obstetric ultrasound examination that uses blind sweeps of a portable ultrasound probe based on external body landmarks. The sweeps were interpreted by five blinded maternal-fetal medicine subspecialists. Sensitivity, specificity, and positive and negative predictive values for blinded ultrasound sweep identification of pregnancy complications (fetal malpresentation, multiple gestations, placenta previa, and abnormal amniotic fluid volume) were compared with a reference standard ultrasonogram as the primary analysis. Kappa for agreement was also assessed. Results: Trainees performed 194 blinded ultrasound examinations on 168 unique pregnant people (248 fetuses) at a mean of 28±5.85 weeks of gestation for a total of 1,552 blinded sweep cine clips. There were 49 ultrasonograms with normal results (control group) and 145 ultrasonograms with abnormal results with known pregnancy complications. In this cohort, the sensitivity for detecting a prespecified pregnancy complication was 91.7% (95% CI 87.2-96.2%) overall, with the highest detection rate for multiple gestations (100%, 95% CI 100-100%) and noncephalic presentation (91.8%, 95% CI 86.4-97.3%). There was high negative predictive value for placenta previa (96.1%, 95% CI 93.5-98.8%) and abnormal amniotic fluid volume (89.5%, 95% CI 85.3-93.6%). There was also substantial to perfect mean agreement for these same outcomes (range 87-99.6% agreement, Cohen range 0.59-0.91, P<.001 for all). Conclusion: Blind ultrasound sweeps of the gravid abdomen guided by an eight-step protocol using only external anatomic landmarks and performed by previously untrained operators with a low-cost, portable, battery-powered device had excellent sensitivity and specificity for high-risk pregnancy complications such as malpresentation, placenta previa, multiple gestations, and abnormal amniotic fluid volume, similar to results of a diagnostic ultrasound examination using a trained ultrasonographer and standard-of-care ultrasound machine. This approach has the potential to improve access to obstetric ultrasonography globally.